Skip to main content
Research

Publications: Mr Christopher Monkhouse

Maclean E, Mahtani K, Honarbakhsh S, Butcher C, Ahluwalia N, Dennis ASC, Creta A, Finlay M et al. ( 2024 ) . Blister Score: A Novel, Externally Validated Tool for Predicting Cardiac Implantable Electronic Device Infections, and Its Cost-Utility Implications for Antimicrobial Envelope Use . Circulation Arrhythmia and Electrophysiology
Monkhouse C, Elliott J, Whittaker-Axon S, Collinson J, Chow A, Moore P, Muthumala A, Honarbakhsh S et al. ( 2023 ) . Detecting deceased patients on cardiac device remote monitoring: a case series and management guide for cardiac device services . Heart Rhythm
Creta A, Ventrella N, Earley MJ, Finlay M, Sporton S, Maclean E, Kanthasamy V, Lemos Silva Di Nubila BC et al. ( 2023 ) . DOACs vs Vitamin K Antagonists During Cardiac Rhythm Device Surgery A Multicenter Propensity-Matched Study . JACC Clinical Electrophysiology vol. 10 , ( 1 ) 121 - 132 .
Monkhouse C, Elliott J, Collinson J, Hunter R, Lambiase P, Ahsan S, Moore P ( 2023 ) . DF-4 defibrillator downgrade to pacemaker, a novel method of device downgrade for implantable cardioverter-defibrillator patients . HeartRhythm Case Reports vol. 9 , ( 8 ) 587 - 589 .
Honarbakhsh S, Protonotarios A, Monkhouse C, Hunter RJ, Elliott PM, Lambiase PD ( 2023 ) . Right ventricular function is a predictor for sustained ventricular tachycardia requiring anti-tachycardic pacing in arrhythmogenic ventricular cardiomyopathy: insight into transvenous vs. subcutaneous implantable cardioverter defibrillator insertion . EP Europace vol. 25 , ( 5 )
Monkhouse C, Wharmby A, Carter Z, Hunter R, Dhinoja M, Chow A, Creta A, Honarbakhsh S et al. ( 2023 ) . Exploiting SMART pass filter deactivation detection to minimize inappropriate subcutaneous implantable cardioverter defibrillator therapies: a real-world single-centre experience and management guide . EP Europace vol. 25 , ( 5 )
Procter WTC, Elliott J, Butt AH, Monkhouse C, Bhuva AN, Moore P ( 2023 ) . Improved delivery of rate‐adaptive pacing using an impedance‐derived contractility sensor in high‐intensity exercise: A case report . Pacing and Clinical Electrophysiology vol. 46 , ( 9 ) 1141 - 1144 .
Wharmby A, Butcher C, Elliott J, Monkhouse C, Goswell C, Lambiase PD ( 2023 ) . Atrial pacing–induced oversensing in subcutaneous implantable cardioverter-defibrillator . HeartRhythm Case Reports vol. 9 , ( 5 ) 276 - 280 .
Ahluwalia N, Graham A, Honarbakhsh S, Tarkas T, Martin S, Monkhouse C, Finlay M, Earley MJ et al. ( 2022 ) . Contemporary Practice and Optimising Referral Pathways for Implantable Cardiac Monitoring for Atrial Fibrillation after Cryptogenic Stroke . Journal of Stroke and Cerebrovascular Diseases vol. 31 , ( 7 )
Griffiths S, Behar JM, Kramer DB, Debney MT, Monkhouse C, Lefas AY, Lowe M, Amin F et al. ( 2022 ) . The long‐term outcomes of cardiac implantable electronic devices implanted via the femoral route . Pacing and Clinical Electrophysiology vol. 45 , ( 4 ) 481 - 490 .
Kanthasamy V, Papageorgiou N, Bajomo T, Monkhouse C, Creta A, Finlay M, Lambiase PD, Moore P et al. ( 2022 ) . Risk factors for developing pacing induced LV dysfunction: Experience from a tertiary center in the UK . Pacing and Clinical Electrophysiology vol. 45 , ( 3 ) 365 - 373 .
Mark N, Papageorgiou N, Ramplin J, Monkhouse C, Moore P, Chow A, Hunter R, Sporton S et al. ( 2021 ) . Feasibility of using his bundle pacing with boston scientific generators . European Heart Journal vol. 42 , ( Supplement_1 )
Sanghvi MM, Jones DM, Kalindjian J, Monkhouse C, Providencia R, Schilling RJ, Ahluwalia N, Earley MJ et al. ( 2021 ) . The utility of implantable loop recorders in patient management: an age- and indication-stratified study in the outpatient-implant era . European Heart Journal - Quality of Care and Clinical Outcomes vol. 8 , ( 7 ) 770 - 777 .
Patel B, Monkhouse C, Manisty C, Papageorgiou N ( 2021 ) . Temporary device malfunction of an MR conditional cardiac resynchronization defibrillator when undergoing MRI without appropriate re-programming: a case report . European Heart Journal - Case Reports vol. 5 , ( 9 )
Honarbakhsh S, Sporton S, Monkhouse C, Lowe M, Earley MJ, Hunter RJ ( 2021 ) . Remote Clinics and Investigations in Arrhythmia Services: What Have We Learnt During Coronavirus Disease 2019? . Arrhythmia & Electrophysiology Review vol. 10 , ( 2 ) 120 - 124 .
Merghani A, Monkhouse C, Kirkby C, Savvatis K, Mohiddin SA, Elliott P, O’Mahony C, Lowe MD et al. ( 2021 ) . Diagnostic Impact of Repeated Expert Review & Long‐Term Follow‐Up in Determining Etiology of Idiopathic Cardiac Arrest . Journal of the American Heart Association vol. 10 , ( 12 )
Vyas S, Monkhouse C, Srinivasan N, Lambiase PD ( 2021 ) . Subcutaneous implantable cardioverter defibrillator lead displacement . Pacing and Clinical Electrophysiology vol. 44 , ( 4 ) 723 - 725 .
Monkhouse C, Cambridge A, Chow AWC, Behar J ( 2020 ) . Pacemaker‐mediated tachycardia in a dual‐lead CRT‐D: What is the mechanism? . Pacing and Clinical Electrophysiology vol. 44 , ( 1 ) 151 - 155 .
Monkhouse C, Cambridge A, Chow AWC, Behar JM ( 2019 ) . High-voltage impedance rise; mechanism and management in patients with transvenous implantable cardioverter-defibrillators: a case series . European Heart Journal - Case Reports vol. 3 , ( 4 ) 1 - 8 .
Monkhouse C, Lambiase P ( 2019 ) . Letter to the Editor—S-ICD oversensing: A fork in the road . Heart Rhythm vol. 17 , ( 5 )
Lim WY, Papageorgiou N, Sukumar SM, Alexiou S, Srinivasan NT, Monkhouse C, Daw H, Caldeira H et al. ( 2019 ) . A nurse‐led implantable loop recorder service is safe and cost effective . Journal of Cardiovascular Electrophysiology vol. 30 , ( 12 ) 2900 - 2906 .
Chapman M, Bates MGD, Behar JM, Williams I, Dewhurst M, Monkhouse C, Hayward C, Muthumala A et al. ( 2019 ) . A Novel Quadripolar Active Fixation Left-Ventricular Pacing Lead for Cardiac Resynchronization Therapy Initial United Kingdom Experience . JACC Clinical Electrophysiology vol. 5 , ( 9 ) 1028 - 1035 .
Hall R, John S, Monkhouse C, Rowland E, Chow A, Lowe M, Behar JM ( 2019 ) . 43 A patient centred evaluation of innovative ambulatory ECG monitoring . Heart . Conference: Cardiac Rhythm Management vol. 105 ,
Dennis A, Moore P, Cambridge A, Monkhouse C, Chow A, Behar JM ( 2019 ) . 47 Pace and ablate strategy in patients with near normal left-ventricular systolic function: PPM or CRT? . Heart . Conference: Cardiac Rhythm Management vol. 105 ,
Hall R, Jones DA, Muthumala A, Weerackody R, Sohaib A, Monkhouse C ( 2019 ) . Transient rise in His-lead threshold due to acute myocardial infarction . PACE - Pacing and Clinical Electrophysiology vol. 42 , ( 6 ) 754 - 757 .
Monkhouse C, Dillon T, Chow AWC, Behar JM ( 2018 ) . AV hysteresis causing initiation of recurrent atrial arrhythmias . Pacing and Clinical Electrophysiology vol. 41 , ( 11 ) 1552 - 1554 .
Monkhouse C, Koutsogeorgis I, Schilling R, Lambiase PD ( 2018 ) . Subcutaneous implantable defibrillator in dextrocardia secondary to Lobectomy . Clinical Case Reports vol. 6 , ( 9 ) 1727 - 1729 .
Monkhouse C, Whittaker‐Axon S, Chow AW ( 2018 ) . Undersensing of ventricular tachycardia in a pacemaker patient: What is the mechanism? . Pacing and Clinical Electrophysiology vol. 41 , ( 5 ) 553 - 556 .